Christoffer Martinsson c77aa6eaaa
All checks were successful
Build and Release / build-and-release (push) Successful in 1m34s
Fix Data_3 timeout by removing sequential SMART during pool detection
Root cause: SMART data was collected TWICE:
1. Sequential collection during pool detection in get_drive_info_for_path()
   using problematic tokio::task::block_in_place() nesting
2. Parallel collection in get_smart_data_for_drives() (v0.1.223)

The sequential collection happened FIRST during pool detection, causing
sda (Data_3) to timeout due to:
- Bad async nesting: block_in_place() wrapping block_on()
- Sequential execution causing runtime issues
- sda being third in sequence, runtime degraded by then

Solution: Remove SMART collection from get_drive_info_for_path().
Pool drive temperatures are populated later from the parallel SMART
collection which properly uses futures::join_all.

Benefits:
- Eliminates problematic async nesting
- All SMART queries happen once in parallel only
- sda/Data_3 should now show serial (ZDZ4VE0B) and temperature

Bump version to v0.1.224
2025-11-30 00:14:25 +01:00
..