All checks were successful
Build and Release / build-and-release (push) Successful in 1m34s
Root cause: SMART data was collected TWICE: 1. Sequential collection during pool detection in get_drive_info_for_path() using problematic tokio::task::block_in_place() nesting 2. Parallel collection in get_smart_data_for_drives() (v0.1.223) The sequential collection happened FIRST during pool detection, causing sda (Data_3) to timeout due to: - Bad async nesting: block_in_place() wrapping block_on() - Sequential execution causing runtime issues - sda being third in sequence, runtime degraded by then Solution: Remove SMART collection from get_drive_info_for_path(). Pool drive temperatures are populated later from the parallel SMART collection which properly uses futures::join_all. Benefits: - Eliminates problematic async nesting - All SMART queries happen once in parallel only - sda/Data_3 should now show serial (ZDZ4VE0B) and temperature Bump version to v0.1.224