All checks were successful
Build and Release / build-and-release (push) Successful in 1m10s
Root cause: SMART data was collected sequentially, one drive at a time. With 5 drives taking ~500ms each, total collection time was 2.5+ seconds. When disk collector runs every 1 second, this caused overlapping collections creating resource contention. The last drive (sda/Data_3) would timeout due to the drive being accessed by the previous collection. Solution: Query all drives in parallel using futures::join_all. Now all drives get their SMART data collected simultaneously with independent 3-second timeouts, eliminating contention and reducing total collection time from 2.5+ seconds to ~500ms (the slowest single drive). Benefits: - All drives complete in ~500ms instead of 2.5+ seconds - No overlapping collections causing resource contention - Each drive gets full 3-second timeout window - sda/Data_3 should now show temperature and serial number Bump version to v0.1.223