Fix Data_3 timeout by removing sequential SMART during pool detection
All checks were successful
Build and Release / build-and-release (push) Successful in 1m34s

Root cause: SMART data was collected TWICE:
1. Sequential collection during pool detection in get_drive_info_for_path()
   using problematic tokio::task::block_in_place() nesting
2. Parallel collection in get_smart_data_for_drives() (v0.1.223)

The sequential collection happened FIRST during pool detection, causing
sda (Data_3) to timeout due to:
- Bad async nesting: block_in_place() wrapping block_on()
- Sequential execution causing runtime issues
- sda being third in sequence, runtime degraded by then

Solution: Remove SMART collection from get_drive_info_for_path().
Pool drive temperatures are populated later from the parallel SMART
collection which properly uses futures::join_all.

Benefits:
- Eliminates problematic async nesting
- All SMART queries happen once in parallel only
- sda/Data_3 should now show serial (ZDZ4VE0B) and temperature

Bump version to v0.1.224
This commit is contained in:
2025-11-30 00:14:25 +01:00
parent 8a0e68f0e3
commit c77aa6eaaa
5 changed files with 10 additions and 17 deletions

View File

@@ -801,20 +801,13 @@ impl DiskCollector {
// Extract base device name (e.g., "sda1" -> "sda")
let base_device = self.extract_base_device(&format!("/dev/{}", device));
// Get temperature from SMART data if available
let temperature = if let Ok(smart_data) = tokio::task::block_in_place(|| {
tokio::runtime::Handle::current().block_on(self.get_smart_data(&base_device))
}) {
smart_data.temperature_celsius
} else {
None
};
// Temperature will be filled in later from parallel SMART collection
// Don't collect it here to avoid sequential blocking with problematic async nesting
Ok(PoolDrive {
name: base_device,
mount_point: path.to_string(),
temperature_celsius: temperature,
temperature_celsius: None,
})
}