Fix Data_3 timeout by removing sequential SMART during pool detection
All checks were successful
Build and Release / build-and-release (push) Successful in 1m34s
All checks were successful
Build and Release / build-and-release (push) Successful in 1m34s
Root cause: SMART data was collected TWICE: 1. Sequential collection during pool detection in get_drive_info_for_path() using problematic tokio::task::block_in_place() nesting 2. Parallel collection in get_smart_data_for_drives() (v0.1.223) The sequential collection happened FIRST during pool detection, causing sda (Data_3) to timeout due to: - Bad async nesting: block_in_place() wrapping block_on() - Sequential execution causing runtime issues - sda being third in sequence, runtime degraded by then Solution: Remove SMART collection from get_drive_info_for_path(). Pool drive temperatures are populated later from the parallel SMART collection which properly uses futures::join_all. Benefits: - Eliminates problematic async nesting - All SMART queries happen once in parallel only - sda/Data_3 should now show serial (ZDZ4VE0B) and temperature Bump version to v0.1.224
This commit is contained in:
6
Cargo.lock
generated
6
Cargo.lock
generated
@@ -279,7 +279,7 @@ checksum = "a1d728cc89cf3aee9ff92b05e62b19ee65a02b5702cff7d5a377e32c6ae29d8d"
|
||||
|
||||
[[package]]
|
||||
name = "cm-dashboard"
|
||||
version = "0.1.222"
|
||||
version = "0.1.223"
|
||||
dependencies = [
|
||||
"anyhow",
|
||||
"chrono",
|
||||
@@ -301,7 +301,7 @@ dependencies = [
|
||||
|
||||
[[package]]
|
||||
name = "cm-dashboard-agent"
|
||||
version = "0.1.222"
|
||||
version = "0.1.223"
|
||||
dependencies = [
|
||||
"anyhow",
|
||||
"async-trait",
|
||||
@@ -325,7 +325,7 @@ dependencies = [
|
||||
|
||||
[[package]]
|
||||
name = "cm-dashboard-shared"
|
||||
version = "0.1.222"
|
||||
version = "0.1.223"
|
||||
dependencies = [
|
||||
"chrono",
|
||||
"serde",
|
||||
|
||||
Reference in New Issue