Fix critical cache key mismatch in smart agent
Cache storage was using keys like 'hostname_service' but lookup was using
'hostname_CollectorName', causing all non-System collectors to fail.
Changes:
- Standardize cache keys to use collector names ('SystemCollector', 'ServiceCollector', etc.)
- Add cache_key() getter method to CachedCollector
- Fix cache lookup to use consistent keys
This should resolve the issue where srv01 only shows System data but no
Services/SMART/Backup data in the dashboard.
This commit is contained in:
parent
b0112dd8ab
commit
996b89aa47
@ -55,6 +55,11 @@ impl CachedCollector {
|
|||||||
self.cache.needs_refresh(&self.cache_key, &self.inner.agent_type()).await
|
self.cache.needs_refresh(&self.cache_key, &self.inner.agent_type()).await
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// Get the cache key for this collector
|
||||||
|
pub fn cache_key(&self) -> &str {
|
||||||
|
&self.cache_key
|
||||||
|
}
|
||||||
|
|
||||||
/// Perform actual collection, bypassing cache
|
/// Perform actual collection, bypassing cache
|
||||||
pub async fn collect_fresh(&self) -> Result<CollectorOutput, CollectorError> {
|
pub async fn collect_fresh(&self) -> Result<CollectorOutput, CollectorError> {
|
||||||
let start = std::time::Instant::now();
|
let start = std::time::Instant::now();
|
||||||
|
|||||||
@ -72,7 +72,7 @@ impl SmartAgent {
|
|||||||
let cached = CachedCollector::with_smart_interval(
|
let cached = CachedCollector::with_smart_interval(
|
||||||
Box::new(smart_collector),
|
Box::new(smart_collector),
|
||||||
Arc::clone(&cache),
|
Arc::clone(&cache),
|
||||||
format!("{}_smart", hostname),
|
"SmartCollector".to_string(),
|
||||||
);
|
);
|
||||||
cached_collectors.push(cached);
|
cached_collectors.push(cached);
|
||||||
info!("SMART monitoring: {:?} (15min intervals)", valid_devices);
|
info!("SMART monitoring: {:?} (15min intervals)", valid_devices);
|
||||||
@ -85,7 +85,7 @@ impl SmartAgent {
|
|||||||
let cached = CachedCollector::with_smart_interval(
|
let cached = CachedCollector::with_smart_interval(
|
||||||
Box::new(system_collector),
|
Box::new(system_collector),
|
||||||
Arc::clone(&cache),
|
Arc::clone(&cache),
|
||||||
format!("{}_system", hostname),
|
"SystemCollector".to_string(),
|
||||||
);
|
);
|
||||||
cached_collectors.push(cached);
|
cached_collectors.push(cached);
|
||||||
info!("System monitoring: CPU, memory, temperature, C-states (5s intervals)");
|
info!("System monitoring: CPU, memory, temperature, C-states (5s intervals)");
|
||||||
@ -101,7 +101,7 @@ impl SmartAgent {
|
|||||||
let cached = CachedCollector::with_smart_interval(
|
let cached = CachedCollector::with_smart_interval(
|
||||||
Box::new(service_collector),
|
Box::new(service_collector),
|
||||||
Arc::clone(&cache),
|
Arc::clone(&cache),
|
||||||
format!("{}_services", hostname),
|
"ServiceCollector".to_string(),
|
||||||
);
|
);
|
||||||
cached_collectors.push(cached);
|
cached_collectors.push(cached);
|
||||||
info!("Service monitoring: {:?} (5min intervals)", service_list);
|
info!("Service monitoring: {:?} (5min intervals)", service_list);
|
||||||
@ -114,7 +114,7 @@ impl SmartAgent {
|
|||||||
let cached = CachedCollector::with_smart_interval(
|
let cached = CachedCollector::with_smart_interval(
|
||||||
Box::new(backup_collector),
|
Box::new(backup_collector),
|
||||||
Arc::clone(&cache),
|
Arc::clone(&cache),
|
||||||
format!("{}_backup", hostname),
|
"BackupCollector".to_string(),
|
||||||
);
|
);
|
||||||
cached_collectors.push(cached);
|
cached_collectors.push(cached);
|
||||||
info!("Backup monitoring: repo={:?}, service={} (15min intervals)", restic_repo, backup_service);
|
info!("Backup monitoring: repo={:?}, service={} (15min intervals)", restic_repo, backup_service);
|
||||||
@ -246,7 +246,7 @@ impl SmartAgent {
|
|||||||
}
|
}
|
||||||
} else {
|
} else {
|
||||||
// Use cached data
|
// Use cached data
|
||||||
if let Some(cached_output) = self.cache.get(&format!("{}_{}", self.hostname, collector.name())).await {
|
if let Some(cached_output) = self.cache.get(collector.cache_key()).await {
|
||||||
if let Err(e) = self.send_metrics(&cached_output.agent_type, &cached_output.data).await {
|
if let Err(e) = self.send_metrics(&cached_output.agent_type, &cached_output.data).await {
|
||||||
error!("Failed to send cached metrics for {}: {}", collector.name(), e);
|
error!("Failed to send cached metrics for {}: {}", collector.name(), e);
|
||||||
}
|
}
|
||||||
|
|||||||